Start Submission

Reading: Coupling Variable Renewable Electricity Production to the Heating Sector through Curtailment...

Download

A- A+
Alt. Display

Technical Articles

Coupling Variable Renewable Electricity Production to the Heating Sector through Curtailment and Power-to-heat Strategies for Accelerated Emission Reduction

Authors:

Vahid Arabzadeh ,

Aalto University, School of Science, New Energy Technologies Group, Espoo, FI
X close

Sannamari Pilpola,

Aalto University, School of Science, New Energy Technologies Group, Espoo, FI
X close

Peter D. Lund

Aalto University, School of Science, New Energy Technologies Group, Espoo, FI
X close

Abstract

The Paris Climate Accord and recent IPCC analysis urges to strive towards carbon neutrality by the middle of this century. As most of the end-use energy in Europe is for heating, or well above 60%, these targets will stress more actions in the heating sector. So far, much of the focus in the emission reduction has been on the electricity sector. For instance, the European Union has set as goal to have a carbon-free power system by 2050. Therefore, the efficient coupling of renewable energy integration to heat and heating will be part of an optimal clean energy transition. This paper applies optimization-based energy system models on national (Finland) and sub-national level (Helsinki) to include the heating sector in an energy transition. The models are based on transient simulation of the energy system, coupling variable renewable energies (VRE) through curtailment and power-to-heat schemes to the heat production system. We used large-scale wind power schemes as VRE in both cases. The results indicate that due to different energy system limitations and boundary conditions, stronger curtailment strategies accompanied with large heat pump schemes would be necessary to bring a major impact in the heating sector through wind power. On a national level, wind-derived heat could meet up to 40% of the annual heat demand. On a city level, the use of fossil fuel in combined heat and power production (CHP), typical for northern climates, could significantly be reduced leading even close to 70% CO2 emission reductions in Helsinki. Though these results were site specific, they indicate major opportunities for VRE in sectoral coupling to heat production and hence also a potential role in reducing the emissions.

How to Cite: Arabzadeh, V., Pilpola, S. and Lund, P.D., 2019. Coupling Variable Renewable Electricity Production to the Heating Sector through Curtailment and Power-to-heat Strategies for Accelerated Emission Reduction. Future Cities and Environment, 5(1), p.1. DOI: http://doi.org/10.5334/fce.58
535
Views
158
Downloads
27
Citations
7
Twitter
  Published on 04 Jan 2019
 Accepted on 06 Dec 2018            Submitted on 20 Sep 2018

Introduction

Renewable energies play an important role in climate change mitigation (International Energy Agency 2017). When introduced massively, integration of renewables on a different scale from stand-alone buildings to cities and nations or regions will be necessary. The challenges ahead with the decarbonization of the energy systems are huge as major part of the carbon emissions needs to be eliminated by the middle of this century. For example, the European Union has planned to reduce its emissions by about 80% to 95% and to reach a 55% share of renewable energy in final energy consumption by 2050 (Oettinger 2012). In addition to carbon emission reductions, access, security, reliability, and affordability need to be addressed in the energy transition (Dastur 2009).

While the clean energy transition is often dominated by variable renewable electricity sources such as solar PV and wind power for power production, the future focus needs also to better include the heating sector, as most of the final energy use is in the form of thermal energy. For example, in Finland over 80% of the final energy use of households is for heating and domestic hot water (Statistics Finland 2018). In Helsinki, which is the capital of Finland, heat constitutes 60% of whole energy production (Lund, Mikkola and Ypyä 2015). Therefore, the role of the built environment in the energy transition will also be important to be considered; measures of interest include building energy efficiency and on-site renewable energy generation (Lund 2012, Cao et al. 2013, Kayo et al. 2014, WBCSD 2009).

Another interesting development is the need to increase energy system flexibility when the share of variable renewable electricity (VRE) increases, which may include measures such as curtailment of VRE for better energy system management, but also to supply heat through power-to-heat (P2H) conversion e.g. when surplus of VRE were available (Lund et al. 2015, IEA 2008, IEA 2009). One may also foresee ‘oversizing’ VRE for the power sector needs to provide high coverage of power demand with VRE during less favorable condition, but then use the surplus or curtailed power at favorable conditions for heating purposes. This would mean increased electrification of the heating sector, and if linked to e.g. heat pumps, providing large amounts of renewable-derived heat to end-users. This kind of sectoral coupling of VRE would increase the energy system flexibility, but reduce emissions in the heating sector as well. Efficient VRE integration has been studied from different aspects (Bessa 2014, Brown 2013, Galus 2013, Sharif 2014, Gao 2008). Other measures such as energy storage and demand response could also be used in this context (Arabzadeh et al. 2018, Lund 2018).

The novelity of the current study is examining of the VRE coupling with the heating sector using different curtailment strategies not yet reported in the literature, in particular for both the national and city level production systems which are included in this study. For the national level analysis, we use Finland as the case to see how the whole heat production portfolio would change with adding large wind power schemes with sector-coupling to heat through curtailment and P2H. For the sub-national level, we use Helsinki city as the case. In this case, considering the energy system in more detail than the national scale will be important, enabling then to assess how the different VRE curtailment schemes may affect the power plant uses. In particular, existing CHP-based energy production system, which is typical for northern cities such as Helsinki, is analyzed, including the running costs and emissions on a yearly scale. Also, the effects of different energy system limitations and building energy efficiency schemes are analyzed.

Methodology

The methodology employed in the study is based on a techno-economic optimization of the energy system, i.e. finding the system configuration which yields the minimum cost under different boundary conditions and limitations. We consider both national (Finland) and sub-national (Helsinki city) levels of the energy production system, for which different optimization techniques will be applied. As clean energy transitions often involve large renewable electricity usage, we take here as the starting point a large wind power scheme. This will be accompanied by different curtailment strategies and power-to-heat conversion to produce carbon-free heat, which is of importance in northern latitudes. Curtailment may also be justified by energy system limitations and power market conditions, thus providing better energy system management.

National model

The national-level analysis is done with a macro-scale energy system model (Pilpola and Lund 2018). The model includes all aspects of an energy system, including electricity, heat, and fuels, thus covering all energy sectors. The model employs a 1-hour step for electricity and heat, while fuel demands are considered on an annual scale. The model seeks for a cost-optimal solution of the energy system while keeping the supply-demand at balance. The optimization problem is defined by Equation (1):

(1)
Minimize Total Annual Cost = t=1tech(Investment                 costt+O&Mt)+t=1fuelsFuel costf+Net cost                 of power import+Emission costs   

The variables in the optimization are the amounts of the fossil primary energy sources and the amounts of conventional conversion, i.e. combined heat and power (CHP), separate production, and heat pumps (HP). The main optimization outputs are the primary energy composition and power and heat production, while the main inputs are historical consumption and temporal data, cost assumptions, and system constraints. The model uses year 2013 as the reference year for input data. A more detailed description of the input data can be found in (Pilpola and Lund 2018). The reference case for the heating sector of interest is shown in Table 1.

Table 1

Heat production in Finland in 2013 (Statistics Finland 2017).

CHP-District heating CHP-Industrial Separate thermal production Residential fuel boilers Residential electric boilers Heat pumps Total

TWh 32.6 3.8 14.6 20.2 14.4 4.6 90.3
% 36 4 16 22 16 5 100

The hourly distribution of the conventional production, such as CHP, is based on historical production data (2013) to mimic the hourly distribution, but their values are scaled to the yearly amounts of energy (PJ, TWh) resulting from the optimization. The operation of the power-to-heat conversion is rule-based, e.g. linked to VRE levels. The level of industrial CHP and residential heat production (fuel and electric boilers), which accounted for 43% of the heat demand in 2013, are assumed non-variable. The model employs three methods for wind power curtailment (described separately). The model also assumes 60 GWh thermal storage available through the Finnish district heating networks filled with water.

Sub-national model

The objective of the sub-national (city) model is to reduce the marginal costs of the local energy production system while introducing variable renewable electricity. The model is based on an optimizer core frame, minimizing a cost function, which is the sum of the production costs, balancing costs, storage costs, and revenues from electricity sales to the Nordic power exchange. Equation (2) shows the cost function:

(2)
Minimize t(Productioncosts+ Balancingcosts + Storagecosts Revenuesfromsales)

The details of the model are described in (Mikkola and Lund 2016). The model includes 3 main sets of constraints: the technical properties of the power plants, technical properties of the balancing methods, and the balance of energy demand and supply. Therefore, the frame is appropriate to model the energy production system. We also incorporated several modifications to the original model to enable a heating sector analysis as follows: Firstly, a limitation for heat storage charging and discharging was defined. Secondly, to account for possible heat source restrictions in case of large heat pump schemes with P2H conversion, we defined a dynamic COP, which drops when entering the peak heat demand period (HP has a COP = 3 whenever the heat demand is <50% of the peak heat demand; COP = 2 for heat production between 50% and 70% of the peak demand; COP = 1, i.e. HP is replaced with an electric boiler, when heat demand is >70% of the peak demand). The annual heat demand in Helsinki (60°N) is 6.6 TWh and the electricity use is 4.4 TWh. Two energy efficiency strategies in buildings will be considered leading to 8% and 16% lower heating demand, respectively. The heat demand profiles will be modified accordingly in these cases by using a scaled U-value for the temperature-dependent part of the heat load. The details of the present energy production plants in Helsinki are shown in Table 2 (Mikkola and Lund 2016). In addition, the district heating system has 5 GWh of storage capacity through its piping network, which can be employed for storing curtailed power in from of thermal energy.

Table 2

Nominal output of energy plants in Helsinki (MW).

CHP gas CHP coal CHP coal Boiler gas Boiler Oil Boiler Coal HP

Power 630 220 160
Heat 580 420 300 360 1900 180 90

Curtailment cases

Three different methods for wind energy curtailment will be employed, illustrated in Figure 1. “Peak-shaving” curtailment is based on shaving a fixed percentage of the wind power peaks. In “Wind-following”, wind power is curtailed with a constant fixed percentage. In “Load-following”, wind power is curtailed above a fixed level (percentage) of the electrical load. The curtailed wind power is used with a power-to-heat (P2H) strategy, i.e. all curtailed wind power will be directed to heat pumps. As wind power is a renewable and zero-marginal-cost resource, we argue that the heat produced by this “forced” heat pump operation offers a renewable and low-cost, albeit non-dispatchable, source of heat, which in turn may have the possibility to decrease the marginal costs of energy production. In the sub-national level, the forced implementation of the HP, limits the available HP capacity for the dispatch optimization.

Figure 1 

Schematic illustration of the different wind power curtailment methods using a curtailment rate of 30% as an example.

Results

In this section, we analyze the effects on the heat production system when applying large wind power schemes and curtailment with the P2H conversion. On the national level, the effect of each curtailment method is discussed in term of system operation and energy conversion. On the sub-national level, the focus is on the heating demand profile modification through building energy efficiency measures in addition to heat resource limitations for heat pumps.

National case

In the national case, the three wind power curtailment strategies described previously resulted in very different levels of curtailed wind power shown in Table 3. Two levels of wind power use were investigated: 20 TWh and 40 TWh, corresponding to 24% and 48% of the yearly electricity use of Finland. The “Peak-shaving” strategy yielded the least heat, even at a high curtailment level. The “Load-following” did not produce any heat with 20 TWh of wind, but clearly more with 40 TWh than the “Peak-shaving” strategy. “Wind-following” gave the highest level of curtailment: With 30% curtailment and 40 TWh of wind it resulted in 36 TWh of heat production, which would account for 40% of the total annual heat demand. Note that the curtailed wind power was used in heat pumps (COP = 3). Figure 2 shows the change in the heat production mix caused by the different curtailment and P2H schemes. The reference case is Finland in 2013, based on historical data. Most cases exhibited increased CHP production (particularly coal-CHP if the CO2 and fuel cost remain low) and decreased separate heat production. As decrease of boiler use was also observed in the cases without curtailment and P2H, it can be stated that this effect was caused by the overall cost optimization, suggesting that with increasing wind power, replacing separate heat boilers with CHP may be cost-effective even without any additional P2H measures. However, including curtailment+P2H would emphasize the role of the heat pumps, i.e. the HP heat production increased in all cases with wind power curtailment. The increase in heat pump production was partly caused by the “forced” wind power curtailment strategy, but also partly by the overall cost optimization. Some CHP would, however, remain despite the increased HP production due to the economic reasons: it may be cost-effective to produce CHP-based electricity to be exported to international markets, even if that may simultaneously lead to oversupply of heat.

Table 3

Heat pump production with curtailed wind power in the national case.

Wind power before curtailment (TWh) Curtailment rate (%) Curtailment method

Peak-shaving (TWh) Wind-following (TWh) Load-following (TWh)

20 TWh 10 0.1 6.0 0.0
30 2.2 18.0 0.0

40 TWh 10 0.1 12.0 4.6
30 4.3 36.0 14.0
Figure 2 

Change in the heat production compared to the national reference case (Finland 2013). “CHP-DH” refers to district heating CHP. Heat pump operation is divided into normal heat pump operation and “forced” heat pump operation using the curtailed wind power.

Figure 2 also illustrates that in cases of a higher amount of wind-power driven (“forced”) heat pump operation, the net change of heat production is positive. As the overall heat demand stayed constant in all cases, this positive net change suggests that part of the additional heat production was wasted. In the “Wind-following” curtailment case, heat production was up to 20 TWh higher than the demand. A part of the excess heat production may appear in the losses of thermal storage, but clearly forced, non-dispatchable heat pump operation was not always able to match the heat demand, which leads to oversupply of heat. Some of the surplus heat could, however, disappear if the COP of the heat pumps were lower than anticipated, which could occur in particular during the peak heating season. Increasing the thermal storage capacity could also help to mitigate the heat surplus.

Sub-national case (Helsinki)

For the sub-national level, the effect of heating demand improvement (energy efficiency), wind curtailment, and heat source limitations of heat pumps were investigated through four scenarios:

  1. Current energy system (90 MW HP, no curtailment, no heat resource limitation);
  2. 1500 MW of heat pumps, no curtailment, no heat resource limitation;
  3. 1500 MW of heat pumps, 30% curtailment, no heat resource limitation;
  4. 1500 MW of heat pumps, 30% curtailment, dynamic COP (heat source limitation).

In all scenarios, building energy efficiency improvements are applied: present building U-value is improved by 10% and 20% leading to 8% and 16% lower heat demand, respectively. The building energy efficiency improvement reflects the potential for energy efficiency in the old building stock, typical to Helsinki. The necessary measures could typically involve better thermal insulation, improved heating control, and/or better windows in the building stock. Moreover, 750 MW and 1500 MW of wind power was introduced to the energy production system, representing 43% and 86% of the yearly electricity demand in Helsinki, respectively. The 1500 MW heat pump scheme covers almost 50% of the peak heat demand, the rest of the peak being supplied through boilers. For comparison, the yearly fuel costs and CO2 emissions are compared with the present system with no measures, for which the system parameters are given in Table 2. The results for Scenario 1 are shown in Table 4. In this section, in all figures, the term “norm” means heat production with heat pump by electrical power and “curt” means the produced heat with heat pump by curtailed wind power.

Table 4

Annual CO2 emissions and fuel cost for different building energy efficiency improvements in the present energy system of Helsinki (Scenario 1).

Case Heat demand reduction (%) Wind (MW) Fuel cost (M€/yr) Emissions (ktCO2/yr)

Present system 327 2271
1 750 296 2232
2 1500 288 2210
3 8 750 273 2137
4 8 1500 264 2112
5 16 750 250 2027
6 16 1500 239 2000

Wind power alone would mainly reduce the gas use, but not coal, because of the need to meet the heat demand (coal-CHP produces more heat than gas-CHP). Also, the price difference between coal (€43/MWh) and gas (€56/MWh) would slightly favor coal. No emission cost was applied, but e.g. a €15/MWh CO2 cost would not change the results due to these system limitations. Wind power would therefore mainly reduce the fuel costs, but marginally the emissions in the Helsinki case with the assumptions used.

Building energy efficiency measures in cases 4 and 6 gave the best results with cost reductions of 19% and 26% and emission decreases of 7% and 12%, respectively. Detailed heat and electricity production are shown in Figure 3, which clearly demonstrates that most of the wind power would go to export to the Nordic power exchange. Note that Helsinki presently produces more electricity than it needs, i.e. some 40% is sold to the market (export).

Figure 3 

Electricity production and heat production of the power plants with different building energy saving levels for Scenario 1 (cases 4 and 6 in Table 4).

In Scenario 2, 1500 MW of heat pumps is added to Scenario 1. Neither curtailment nor limitation of heat sources for heat pumps is included here. Table 5 presents the key results.

Table 5

Annual CO2 emissions and fuel cost for building energy efficiency improvements and 1500 MW of heat pumps (Scenario 2).

Case Heat demand reduction (%) Wind (MW) Fuel cost (M€/yr) Emissions (ktCO2/yr)

Present system 327 2271
1 750 204 1270
2 1500 162 1010
3 8 750 194 1234
4 8 1500 154 983
5 16 750 184 1201
6 16 1500 146 957

Adding a large heat pump scheme would significantly reduce the yearly fuel costs and emissions, whereas adding building energy efficiency measures on the top of that had less effect. In the best case 6, the fuel costs and emission dropped by 55% and 58%, respectively. Figure 4 demonstrates details of the energy production for the Scenario 2. There are slight differences only between cases 4 and 6, which indicates that reducing the heat demand from 8% to 16% does not have any major effect on the operation of the energy production system. Integration of the wind power reduces the gas electricity production by about 42% and the coal electricity production about 70%, respectively. The gas heat production is reduced by 31% and coal heat production is cut 77%. The HP heat production increases by 70%. The heat storage use increased by 70%, i.e. the number of charging-discharging cycles of the 5 GWh capacity in the DH network increased substantially.

Figure 4 

Electricity production and heat production of the power plants with different building energy saving levels and 1500 MW of heat pumps for Scenario 2 (cases 4 and 6 in Table 5).

In Scenario 3, wind energy curtailment was introduced to Scenario 2. The resulting fuel cost and emissions are in Table 6.

Table 6

Annual CO2 emissions and fuel cost for the case with building energy efficiency improvements, 1500 MW of heat pumps, and 1500 MW of wind power with curtailment (Scenario 3).

Case Heat demand reduction (%) Curtailment method Curtailment (%) Fuel cost (M€/yr) Emissions (ktCO2/yr)

Present system 327 2271
1 Peak-shaving 10 145 950
2 Peak-shaving 30 142 925
3 8 Wind-following 10 140 752
4 8 Wind-following 30 118 727
5 16 Load-following 10 111 727
6 16 Load-following 30 110 710

Figure 5 demonstrates the details of the effects on the energy production system. The largest reductions in the fuel cost and emissions were for case 6, 66% and 68%, respectively, when the “Load-following” curtailment method was used, though the difference to “Wind-following” curtailment was small. The heat production by coal was dramatically cut to less than 10% of the yearly heat production (–84%); the gas use dropped below 30% (–47%), respectively. The reduced coal and gas use lead to significantly reduced emissions (66-68% from the present). Heat pumps are the dominating heat production method in cases 4 and 6, which leads to a slight increase in electricity imports.

Figure 5 

Electricity production and heat production of the power plants with different building energy savings, 1500 MW of heat pumps, and wind curtailment for Scenario 3 (cases 2, 4 and 6 in Table 6).

In Scenario 4, we added a heat source limitation to heat pumps by using a dynamic COP explained earlier to reflect the changes in the heat source availability for the heat pumps. An electric boiler with a maximum output of 1500 MW (equal to COP = 1) was therefore added to the energy production system. Table 7 presents the results for Scenario 4.

Table 7

7 Annual CO2 emissions and fuel cost for energy system with a HP with capacity as function of the heat demand (wind energy = 1500 MW and curtailment = 30%) (Scenario 4).

Case Heat demand reduction (%) Curtailment method Fuel cost M€/yr Emissions (ktCO2/yr)

Modified system 0 298 1843
1 0 Peak-shaving 159 994
2 8 Peak-shaving 150 955
3 16 Peak-shaving 141 922
4 0 Wind-following 139 855
5 8 Wind-following 128 802
6 16 Wind-following 117 750
7 0 Load-following 136 841
8 8 Load-following 127 805
9 16 Load-following 119 769

The reference case in this scenario is a modified system since the nominal maximum HP output is set as 1500 MW. For each curtailment method, the lowest fuel cost and emission were achieved with the highest heat demand improvement of 16% (case 3, 6 and 9). The details of the energy production for Scenario 4 are shown in Figure 6. The base system in this scenario is the modification of the present system (1500 MW heat pumps), but electric boilers are used in cases 6 and 9 due to heat source limitations. In case 9 with the “Load-following” curtailment scheme, there is no heat storage use at all. It seems that increasing the wind energy share would reduce the contribution of the heat storage in this case. Both the share of gas and coal in heat production is halved compared to the base system; the share of gas comes down to 25% and coal to 5% of the yearly heat consumption. In power production, we see the similar trend: the share of gas power production is halved compared to the base system to 43% of power consumption and coal 5%, respectively. Due to the heat resource limitation, a part of the heat consumption from curtailed wind power is supplied by the electric boiler. For the “Load-following” curtailment (case 9), the electric boiler contribution is 18%. In Figure 6, the term “curt” and “norm” for the electrical boiler deal with heat production by electrical power and produced heat with curtailed wind power.

Figure 6 

Electricity production and heat production of the power plants with different building energy savings, 1500 MW of heat pumps, wind curtailment, and dynamic heat pump COP for Scenario 4 (cases 6 and 9 in Table 7). The base system is here a modification of the present system.

Conclusions

In this paper, we have studied the sectoral coupling of variable renewable energy (VRE) to the heating sector on a national (Finland) and city (Helsinki) level. For VRE, we used a large wind power scheme to which different curtailment & P2H strategies, building energy efficiency measures, and heat pump schemes were added. The effects to the existing energy system were analysed with dynamic energy system models. On the city level, four basic scenarios with a total of 27 cases were analyzed to reveal the system effects from the above strategies, while on the national level 14 cases were analyzed. The main findings of the analyses are the following:

  • On the national scale, the system inertia is typically larger than on a city level, leading to more ideal spatiotemporal integration of VRE, i.e. stronger smoothing effects of VRE. Therefore, the sectoral coupling of VRE to the heating sector produced larger impacts on the national scale. On a city-level, the simulations better considered the dynamics of individual power plants and the consequent limitations, which is most likely the reason why the impacts were smaller than on a national scale, where all plants were handled in a lumped way.
  • The amount of VRE-based heat strongly depends on the type of curtailment strategy chosen, e.g. mere ‘Peak-shaving’ would typically produce the least heat and ‘Wind-following’ the most.
  • On the national level, the most effective curtailment strategy (‘Wind-following’, 30%) with P2H conversion and 40 TWh of wind power was able to cover up to 40% of the yearly heat demand (the initial wind power production corresponding to 48% of the yearly electricity consumption). The P2H strategy with wind power also replaced separate heat boilers.
  • On the city level, with a 1500 MW wind power scheme (corresponding to 86% of the yearly electricity use in Helsinki) and the ‘best’ curtailment strategy (Scenario 3 and 4), wind power and wind-power derived heat were able to radically modify the existing use of the fossil-based CHP plants, which led to close to 70% emission reductions.
  • In the city-level analyses, adding wind power to the Helsinki case with a CHP dominated energy system would actually increase the export of electricity. Wind power would replace more gas-CHP than coal-CHP, the latter being more important to the heat production.
  • On the city-level, improving the building energy efficiency 10%–20% of the yearly heat demand did only marginally reduce the annual fuel costs and emissions, which is a result of the energy system dynamics.

The heat pumps played a major role in the sectoral coupling of VRE to the heating sector. On a national level the heat pumps were assumed to work at a constant COP, but on the city level we employed a dynamic COP which considers heat source limitations. The assumption of a constant COP may lead to too optimistic values of heat production, but as this also caused oversupply of heat which couldn’t be utilized, the error to the energy balance is probably minor.

Acknowledgements

This work was supported by the Nordic Energy Research [grant number 76084] and the Academy of Finland [grant number 285353].

Competing Interests

The authors have no competing interests to declare.

References

  1. Arabzadeh, V, Alimohammadisagvand, B, Jokisalo, J and Siren, K. 2018. A novel cost-optimizing demand response control for a heat pump heated residential building. Building Simulation, 11(3): 533–547. DOI: https://doi.org/10.1007/s12273-017-0425-5 

  2. Bessa, R, Moreira, C, Silva, B and Matos, M. 2014. Handling renewable energy variability and uncertainty in power systems operation. WIREs Energy and Environment, 3: 156–178. DOI: https://doi.org/10.1002/wene.76 

  3. Brown, MA and Zhou, S. 2013. Smart-grid policies: An international review. WIREs Energy and Environment, 2: 121–139. DOI: https://doi.org/10.1002/wene.53 

  4. Cao, S, Hasan, A and Siren, K. 2013. On-site energy matching indices for buildings with energy conversion, storage and hybrid grid connections. Energy and Buildings, 64: 423–438. DOI: https://doi.org/10.1016/j.enbuild.2013.05.030 

  5. Dastur, A and Suzuki, H. 2009. Eco2 cities ecological cities as economic cities. Washington: World Bank. 

  6. Galus, MD, Vayá, MG, Krause, T and Andersson, G. 2013. The role of electric vehicles in smart grids. WIREs Energy and Environment, 2: 384–400. DOI: https://doi.org/10.1002/wene.56 

  7. Gao, L, Wu, H, Jin, H and Yang, M. 2008. System study of combined cooling, heating and power system for ecoindustrial parks. International Journal of Energy Research, 32: 1107–1118. DOI: https://doi.org/10.1002/er.1448 

  8. International Energy Agency. 2008. Energy Technology Perspectives: Scenarios and Strategies to 2050. Paris: OECD/IEA. 

  9. International Energy Agency. 2009. Cities, Towns & Renewable Energy: Yes in My Front Yard. Paris: OECD/IEA. 

  10. International Energy Agency. 2017. World Energy Outlook 2017. Paris: IEA. 

  11. Kayo, G, Hasan, A and Siren, K. 2014. Energy sharing and matching in different combinations of buildings, CHP capacities and operation strategy. Energy and Buildings, 82: 685–695. DOI: https://doi.org/10.1016/j.enbuild.2014.07.077 

  12. Lund, P. 2012. Large-scale urban renewable electricity schemes – Integration and interfacing aspects. Energy Conversion and Management 63: 162–172. DOI: https://doi.org/10.1016/j.enconman.2012.01.037 

  13. Lund, PD. 2018. Capacity matching of storage to PV in a global frame with different loads profiles. Journal of Energy Storage, 18: 218–228. DOI: https://doi.org/10.1016/j.est.2018.04.030 

  14. Lund, PD, Lindgren, J, Mikkola, J and Salpakari, J. 2015. Review of energy system flexibility measures to enable high levels of variable renewable electricity. Renewable and Sustainable Energy Reviews, 45: 785–807. DOI: https://doi.org/10.1016/j.rser.2015.01.057 

  15. Lund, PD, Mikkola, J and Ypyä, J. 2015. Smart energy system design for large clean power schemes in urban areas. Journal of Cleaner Production, 103: 437–445. DOI: https://doi.org/10.1016/j.jclepro.2014.06.005 

  16. Mikkola, J and Lund, PD. 2016. Modeling flexibility and optimal use of existing power plants with large-scale variable renewable power schemes. Energy, 112: 364–375. DOI: https://doi.org/10.1016/j.energy.2016.06.082 

  17. Oettinger, G. 2012. Energy roadmap 2050. 1st ed. Belgium: Publications Office of the European Union. 

  18. Pilpola, S and Lund, PD. 2018. Effect of major policy disruptions in energy system transition: Case Finland. Energy Policy, 116: 323–336. DOI: https://doi.org/10.1016/j.enpol.2018.02.028 

  19. Sharif, A, Almansoori, A, Fowler, M, Elkamel, A and Alrafea, K. 2014. Design of an energy hub based on natural gas and renewable energy sources. International Journal of Energy Research, 38: 363–373. DOI: https://doi.org/10.1002/er.3050 

  20. Statistics Finland. 2017. Energy table service. Available at: http://pxweb2.stat.fi/sahkoiset_julkaisut/energia2015/html/engl0000.htm [Last accessed 21 August 2016]. 

  21. Statistics Finland. 2018. Cold weather raised energy consumption in housing in 2016, 1 February 2018. Available at: https://www.stat.fi/til/asen/2016/asen_2016_2017-11-17_tie_001_en.html [Last accessed 25 June 2018]. 

  22. World Business Council for Sustainable Development (WBCSD). 2009. Energy efficiency in buildings: Transforming the market. Switzerland.